- Home > Supply Leads > Horizontal-the Vertical Flame Chamber Tester, horizontal and vertical
- Product Categories
- 1 @. Burning like fire-reta..
- 2 @. Electrical protection ..
- 3 @. Electrical Safety Test..
- 4 #. Electromagnetic Compat..
- 5 # German PTL Testing Mach..
- 6 ¥. Wire and cable testin..
- 7 &. Sensor Series
- 8 *. Torque Tester
- 9 (. LED light color electr..
- 10! . Head gauge series
- 11 # Electronic measuring i..
- 13 gauge *. Lamp holder
- 14.VDE gage
- ※ ※ needle sales testing ..
- 58: Needle flame tester
- 72: Glow-wire test apparatus
- 89: standard test instrument
- 77: Spring impactor
- 85: Tracking Tester
- Ball Pressure Test
- Japan NMB sensor
- U.S. AST Pressure Sensors
- Load cell
- Pressure sensor
- Canada GM88 display instrum..
- 68: horizontal and vertical..
- Crystal tester / crystal te..
- Test Probe
- The thermocouple temperatur..
- Creepage distance test card
- Plug torque tester
- Thermocouple
- Spray Nozzle
- Stability test rig
- Anti-strength tester
- Horizontal-the Vertical Flame Chamber Tester, horizontal and vertical
-
1, burner: inner Φ 9.5 mm + / ??-0.3 mmBunsen one.
2, the test Angle: 0 °, 20 °, 45 ° manual switching.
3, flame height: 20 mm ± 2 mmto180 mm ± 10 mmis adjustable.
4, ShiYan time: 0-999.9 s + / -0.1 s adjustable.
5, YuYan time: 0-999.9 s + / -0.1 s, automatic records, wire control pause.
6, the burning time: 0-999.9 s + / -0.1 s, automatic records, wire control the pause.
7, burning gas: 98% methane gas or 98% propane (generally can use liquefied petroleum gas (LPG) instead of).
8, flow pressure: with double flow and pressure gauge (gas and air)
9, temperature test, range: 0 ~ 1000 ℃
10, the flame temperature requirements: from100 ℃ ± 5 ℃ went up to700 ℃ ± 3 ℃ time in 44 ± 2 seconds and 54 seconds ± 2 seconds.
11, temperature measurement thermocouple: K type Φ0.5 mmprecision plus or minus 0.05%.
12, test process: test procedures manual control, independent convulsions
13, consult standard: UL 94 2006, IEC 60695-11-3, IEC 60695-11-4, GB/T5169.15, 16, 17, 22-2008
14, the studio volume: more than 0.75 cubic (can be customized to the other size)
15, the equipment size: 1200 mmwide x700 mmdeep x1400 mmhigh
16, control: the single chip microcomputer + touch screen control, the high accuracy thermometer independent type electrical control system, strong anti-jamming capability.
17, operation efficiency: test control processes to achieve a key type operation, fast and efficient test.
18, the testing distribution standard integration: according to actual test process writing test procedures.
19 automatic: automatic ignition.