Index marks of electric tester AUTO-LD power index of test marks
Marks of the Index tester electrical / electronic traces of the index test
Electrical tester marks the basic profile of index: index of power mark experiment is IEC60112, UL 746A, GB/T4207, GB4706.1 ASTM D
3638-92 simulation and other standards for the pilot project.
Index marks of electric tester details
Tracking tester
Basic Profile:
Tracking test (index of power mark experiment) is IEC60112, UL 746A, GB/T4207, GB4706.1 ASTM D
3638-92 simulation and other standards for the pilot project.
Tracking test (index of power mark experiment) is on the surface of the solid insulating material, the required size (2mm × 5mm) between platinum electrodes, applied voltage and a time (30s) set height (35mm
) Drops the volume of conductive liquid droplets provisions (0.1% NH 4 CL), for the evaluation of the surface of the solid insulating material in electric and wet or contaminated media under the combined effects of the anti-leakage performance, measured power traces of the index compared to
(CT1) and resistance index of electrical traces (PT1).
Tracking tester (electric meter mark of the index test) instrument for lighting, low voltage electrical appliances, household appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, equipment, information technology, research, production and quality control departments , also applies to insulating materials, engineering plastics, electrical connectors, accessories industry.
Technical parameters:
1, electrode materials: electrodes - platinum metal (platinum)
2, electrode pressure: 1.0 ± 0.05N
3, electrode distance: 4.0mm ± 0.01mm, angle 60 ° ± 5
4, electrode voltage: 100 ~ 600V (48 ~ 60HZ) adjustable short-circuit current at 1.0 ± 0.1A when the voltage drop is less than 10%
5 drops of liquid height: Adjustable to 30 ~ 40mm
6 drops of liquid size: 44 to 55 drops / 1cm3 adjustable
7, the drip time: 30s ± 5s,
8, the number of drops of liquid: adjustable from 0 to 9999 times
9, leakage judge: loop current greater than 0.5A and maintain the relay for 2 seconds then cut off the current, indicating that the sample failed
10, the testing process: automatic control testing procedures, independent ventilation
11, reference standards: IEC60112, GB/T4207, GB4706.1
12, studio size: 0.1m3 (can be customized according to different criteria 0.5 m3 or 0.75m3)
13, equipment, dimensions: 630mm wide × 390mm deep × 1250mm high
Contact Precision Instrument Co., Ltd. Odyssey record
Contact: Mr. Wu
Tel: 15014035973 0755-26566158
Fax 755 -26978981
Mobile: 15014035973
Company Address: Guangdong Province, Shenzhen Baoan District Xixiang Industrial Park, four landslide
Email: andi153@yahuoo.cn
Postal Code: 518052
Website: http://www.auto17.cn
QQ: 460926526